The scope of the evaluation was to ascertain the fuel saving in calculating the efficiency of the low voltage, low level OmniDEL electric binlift v’s the OmniDEL hydraulic variant.
The evaluation was conducted at a customer site, in a municipal council environment.
The study consisted of a collection period of 2 weeks, changing then the binlift variant for a further 2 week evaluation.
MILES |
FUEL [LITRES] |
TONNES |
BINS |
MPG [Ave] |
LITRES |
|
---|---|---|---|---|---|---|
Electric Binlift | 304.48 | 548.80 | 292.98 | 13,246 | 2.52 | 1.87 |
Hydraulic Binlift | 306.34 | 638.60 | 311.06 | 13,991 | 2.18 | 2.05 |
Variance | -0.6% | -16.4% | -6.2% | -5.6% | 13.5% | 8.8% |